Flowline Smart Trak, Switch Trek, and Switch Pak lines offer intrinsically safe or general-purpose liquids level detection. These models are contact sensors that are reliable and designed with level switch or control, pump protection, spill prevention, and detection or alarms. They are ideal for chemical, water, wastewater, and oil applications.
The package includes an intrinsically safe or general-purpose multi-point level switch, offering liquid level detection up to 10’ (3m). It features 1-4 adjustable level switch points and comes with a compact junction box for wiring termination. With three sensor technologies available, choose the type that best suits your application media. Opt for ultrasonic for chemicals and light-weight oils, vibration for wastewater with light coating or scaling, and buoyancy for clean water and non-coating chemicals.
The general-purpose level switch package facilitates automatic tank filling or emptying within a range of up to 10’ (3m) between two adjustable level switch points. The compact relay controller, optionally equipped with a strobe, includes one latching 16A relay for pump or valve control. With three sensor technologies available, choose the type that best suits your application media. Opt for ultrasonic for chemicals and lightweight oils, vibration for wastewater with light coating or scaling, and buoyancy for clean water and non-coating chemicals.
The package includes an intrinsically safe or general-purpose point level switch, offering high or low liquid level detection with one relay or reed switch output. It features a compact junction box for wiring termination. With three level sensor technologies available, choose the sensor type based on your application media and classification. Opt for ultrasonic for chemicals and lightweight oils, vibration for wastewater with light coating or scaling, and buoyancy for clean water and non-coating chemicals.
The point level switch package for general purposes offers high or low liquid level detection with a single 16A compact relay controller designed for pump or valve shut-off. The optional flash alarm is available to draw attention to alarm conditions. With three level sensor technologies to choose from, select the sensor type based on your application media. Opt for ultrasonic for chemicals and lightweight oils, vibration for wastewater with light coating or scaling, and buoyancy for clean water and non-coating chemicals.
CSA-approved for hazardous locations, the intrinsically safe ultrasonic point liquid level switch offers high or low liquid level detection for chemicals, solvents, or low-viscosity petroleum-based liquids, featuring a 1A relay output. Examples of applicable media include hydrochloric acid, acetone, and diesel fuel oil. The submersible PP or PFA level switch sensor can be universally mounted either through the tank wall or inside the tank, connecting to a PLC or relay controller.
The general-purpose vibration point liquid level switch offers high or low liquid level detection for dirty liquids or those with light to medium coating or scaling characteristics, featuring a 1A relay output. Media examples encompass wastewater, diluted caustic soda, and copper sulfate. To ensure optimal performance, the sensor automatically adapts to coating buildup and, if required, triggers a proactive maintenance alarm to request cleaning. The submersible PP-Ryton® level switch sensor can be universally mounted either through the tank wall or inside the tank, connecting to a PLC or relay controller.
The general-purpose guard capacitance point liquid level switch offers high or low liquid level detection for water-based conductive liquids with light coating, crystallizing, or scaling characteristics, featuring a 1A relay output. Examples of applicable media include copper sulfate and brine. For optimal performance, it is recommended to install the sensor vertically, and the RF guard circuit eliminates the coating signal path between the active and reference electrodes. The submersible polypropylene liquid level sensor can be mounted inside the tank or through non-metallic tank walls, serving as a high-level alarm or low-level alarm.
The general-purpose float point liquid level switch delivers high or low liquid level detection for relatively clean water and chemical solutions, featuring a 15VA reed switch output. Media examples encompass potable water and boric acid. To address turbulence-induced level switch chatter, the baffle body is incorporated. The submersible PP or PVDF level switch sensor is vertically mounted inside the tank and connected to a PLC or relay controller.
The general-purpose optic leak switch is designed for liquid leak detection in and around secondary containment sumps, tanks, and piping systems, offering a 1A relay output. Examples of applicable media include sulfuric acid and sodium hypochlorite. The submersible PP or PFA leak switch sensor is installed either through the containment wall or within the interstitial space and connected to a PLC or relay controller.